cpclean

CPCLEAN(1)                           HUGIN                          CPCLEAN(1)



NAME
       cpclean - Remove wrong control points by statistical methods

SYNOPSIS
       cpclean [options] input.pto

DESCRIPTION
       cpclean uses statistical methods to remove wrong control points.

       Step 1 optimises all images pairs, calculates for each pair mean and
       standard deviation and removes all control points with error bigger
       than mean+n*sigma.

       Step 2 optimises the whole panorama, calculates mean and standard
       deviation for all control points and removes all control points with
       error bigger than mean+n*sigma.

OPTIONS
       --output|-o output.pto
           Output Hugin PTO file. Default: '<filename>_clean.pto'.

       --max-distance|-n num
           distance factor for checking (default: 2)

       --pairwise-checking|-p
           do only pairwise optimisation (skip step 2)

       --whole-pano-checking|-w
           do optimise whole panorama (skip step 1)

       --dont-optimize|-s
           skip optimisation step when optimising the whole panorama

       --check-line-cp|-l
           also include line control points for calculation and filtering in
           step 2

       --help|-h
           shows help

AUTHORS
       Thomas Modes



"Version: 2019.2.0"               2020-01-28                        CPCLEAN(1)